Subdivision: MAHOGANY VALE AT PEREGRINEFiling: 1Subdivision Number: 461
Business Name
Address:8010 APPLESTONE TR
DP No:AR NV 21-00216Zone:PUDOverlay:HS
TSN:7303301004
Required Landscape:Fire Codes:FUELS/A-ROOF

Plantrac Reviews

New,
Add,
Rem
Date In Date Out Status Reviewer Contractor Comments
AR05/04/20215/4/2021AKLSHOMEOWNERThe applicant requests to build a new attached garage addition to include a total of 5 garage car door entries between existing and proposed garage space (Existing garage has a double and single car garage door; proposed garage has a 2 single doors; totaling 5).
Rem05/04/20215/7/2021 4:55:00 PMAKLSN BAR B CONSTRUCTION, LLCapproval for attached 672 sf garage addition to existing home; meets setbacks and lot coverage 9.45%; no disturbance to 10' drainage/utility easement; total 5 car door entries per approved ARNV21-00216; height not to exceed existing garage; City does not regulate HOA covenants
Rem03/29/20214/1/2021 1:52:00 PMDKLSN BAR B CONSTRUCTION, LLCConfirm whether this is total PROPOSED or total existing AND proposed garage door entries. Please itemize in notes how many existing garage door car entries there are and how many proposed to ensure not exceed 4 car entry total between existing and proposed. Conflicting door types in architectural drawing elevation and site plan elevation. And existing door shown in elevation is only single door. Does existing garage have single door AND double door? Otherwise site plan and elevations ready for approval kerri.schott@coloradosprings.gov
Rem03/03/20213/8/2021 11:59:00 AMDKLSN BAR B CONSTRUCTION, LLC1. Show existing garage dimensions; per El Paso County Records existing garage is 985 sf. 985sf plus proposed 672sf exceeds the maximum allowable garage sf of 1650 per City Code. Therefore clearly show existing garage dimensions on site plan to ensure not exceeding 2. driveway slope should not exceed 20% per code 7.3.504 3. Address any comments from SWENT, if any. Will send once received kerri.schott@coloradosprings.gov
Rem12/28/202012/29/2020 4:50:00 PMDKLSN BAR B CONSTRUCTION, LLC1. Indicate source of contour information on site plan 2. Show property line dimensions/locations per plat 3. Show utilities 4. Indicate the existing garage sf to ensure total garage space between existing and proposed does not exceed 1200 sf garage space plus 450 sf garage storage. Also note the total number of garage door entries between existing and proposed 5. Indicate permanent fixed benchmark 6. Show existing and proposed grade and indicate in legend 7. Show drainage patterns; indicate with arrows in legend 8. Note finish floor elevation of new garage 9. Will there be any changes to existing driveway? If not, please note. IF so, show width of driveway at property line, show grade percentage, indicate driveway percentage within front yard setback 10. Will any vegetation be removed? Please note and show what tree type/location will be exist or be removed 11. Identify BG/FG values at each corner of proposed garage 12. Elevation drawings need to show existing grade line and finished grade line (should match values noted at corners on site plan) 13. Show max allowable height of 35 measured from existing grade line on each elevation drawing (contact me if you need example) 14. Show finish floor level on each elevation drawing 15. Will any retaining walls be proposed? If not, make note. If so, show on site plan. kerri.schott@coloradosprings.gov
NEW02/07/19972/7/1997AGGPBOB DAVIS
NEW12/09/199612/9/1996DGGPBOB DAVISSEE HS ACCORDION FILE FOR DETAILED COMMENTARY.