SubdivisionFiling: Subdivision Number:
Business Name
Address:2020 Ridgeway AV
DP No:Zone:R16Overlay:HS
TSN:7435211013
Required Landscape:Fire Codes:

Plantrac Reviews

New,
Add,
Rem
Date In Date Out Status Reviewer Contractor Comments
Rem03/25/20213/30/2021 12:46:00 PMAKLSRATHERT INC.approval of detached 750 sf garage. all design standards met; all grading must conform to already approved GECP
Rem03/16/20213/22/2021 7:09:00 PMDKLSRATHERT INC.1. Sign/date hillside certification statement 2. Show the (BG)/FG values at the corners of proposed structure, not just FG. Should coordinate with the elevation drawings 3. Because roof pitch shown is 4:12, max allowable height is 16' not 20 from existing grade. Adjust max height limit box from 20' to 16' on each elevation drawing 4. Please indicate the distances from the structure to property lines (west and south) with an actual line or arrow to better identify the measurement. Address comments from SWENT (*Because an already approved GECP is included with building permit; PE stamp is not required on hillside site plan)
Rem03/01/20213/3/2021 2:50:00 PMDKLSRATHERT INC.This lot is zoned R1-6 HS. Insufficient hillside site plan. emailed to contact on file. This lot is corner lot; therefore has 2 front yard setbacks of 25', rear setback of 25' and one side setback of 5'. This lot requires a geo hazard for detached structure. The lot is not located within CGS landslide area therefore ELIGIBLE for geo hazard waiver if all 3 waiver criteria are met. contact kerri.schott@coloradosprings.gov
Rem02/23/20213/3/2021 2:59:00 PMDKLSRATHERT INC.insufficient hillside site plan (emailed to contact on file). must meet setbacks (corner lot has two front yard setbacks of 25' and accessory structure cannot be within front yard setback). need approved geo hazard for detached structure in hillside overlay. this lot is eligible for geo hazard waiver if all 3 waiver criteria are met. contact kerri.schott@coloradosprings.gov
Add06/06/20126/6/2012AMKMAdd deck, 7' max ht, uncovered